Fast Clamp-On CTs

fast hinged clamp on current monitorsPearson Electronics is pleased to introduce two new Wide-Band Hinged Clamp-on Current Monitors with fast rise times.  The models 8585C and 8590C feature a 2.0 and 2.5 nanosecond rise times, a ½ inch and 1 inch aperture, and are hinged for easy operation. The new design incorporates Pearson’s wide band frequency response in a demountable configuration for use on fixed conductors.

Both models have a 1.0 V/A sensitivity, a 3dB bandwidth from approximately 1.0 KHz to 200 MHz, and a 5 Ampere rms current rating. Accuracy of 1%, or less, is obtainable across the mid-band.  Pulse currents up to 500 Amperes can be viewed. Other new hinged clamp-on designs feature a range of transfer impedance from 0.01 V/A to 1.0 V/A allowing for accurate measurements at lower frequencies.  A typical model has a 3 dB bandwidth of 25Hz to 15 MHz, with some models as low as 5 Hz.  All of the new hinged clamp-ons are featured in our Clamp-on Current Monitor section along with existing custom and stock designs.

 

 

Upcoming Events

BIOMEDevice
Dec 6-7, 2011 | San Jose, CA


Applied Power Electronics
Feb 5-9, 2012 | Orlando, FL


Int'l Particle Accelerator
May 20-25, 2012 | New Orleans, LA
 
Power Modulator & High Voltage
June 3-7, 2012 | San Diego, CA
 
EMC 2012
Aug 5-10, 2012 | Pittsburgh, PA

 

Particle Accelerator
The Particle Accelerator community uses Pearson Current Monitors for a variety of applications in the area of high . . .
 
Medical Applications
The medical equipment industry uses Pearson Current Transformers in several applications. These include medical. . .
 
Power Industry
The Power Industry uses Pearson Current Transformers to measure transients in switching gear and the observation of. . .
 
EMC Industry
Pearson Clamp-on Current Probes are used to make accurate AC current measurements to meet many of the EMI standards. . .
 
Plasma Research
Pearson Current Probes are used by the Semiconductor and Semiconductor Equipment Industry to make measurements at. . .
 
Capacitive Discharge
Pearson Current Monitors are used to view faithful waveforms and make accurate current measurements from a capacitive. . .
 
Surge Current Testing
Wide Band Current Probes measure surge and in-rush currents for EMC and other industries. A typical requirement. . .
 
Lightning Discharge
Broad Band Current Transformers | Monitors are used to characterize lightning strikes at the Kennedy Space Center and leading. . .
 
Beam Instrumentation
Custom Wide Band Current Monitors are use beam tube applications with our large aperture clamp-on Current Monitors. . .