+1 (650) 494-6444
sales@pearsonelectronics.com

Current Monitor

Current Transformer | Current Probe | Current Transducer
Current Toroid | Current Sensor | Pulse Current Monitor
High Frequency Current Transformer

 

Accuracy ±1% or better, initial pulse response for all models, with a high impedance load such as 1 megOhm in parallel with 20 pF. A 50 Ohm termination will reduce the output to half. All models listed below come with a BNC connector except as noted and are to be used with a 50 Ohm coaxial cable. The current monitor case is conductive and not insulated. Adequate insulation must be provided on the conductor being monitored. To avoid electrical shock, do not mount or remove the current monitor from a live conductor.

 

 



Model #
 



Shape

(click to
expand)



Output
(Volts/
Amp)




Hole Id.
(inches)

 

Time Domain Parameters

 

Frequency Domain Parameters


Peak
Curr.

(Amps)



Droop
(%/µsec.)

Useable
Rise
Time

(nsec.)



IT Max.
(Amp-sec.)

Max.
RMS
Curr.

(Amps)

3dB
pt.
Low

(Hz)

3dB
pt.
High

(MHz)

I/f
(peak
Amps
/Hz)

I2t max
(Amps
squared
 sec)

8585C
N
1.0
0.5
 
500
1.0
2
0.003
 
5
1,500
200
0.01
5
4100C
N
1.0
0.5
 
500
1.0
15
0.0015
 
5
1,500
25
0.008
150
7790
M
1.0
1.0
 
500
1.0
15
0.002
 
5
1,500
25
0.01
150
4688
L
1.0
2.0
 
500
0.4
12
0.005
 
15
600
30
0.03
150
7805
K
1.0
4.0
 
500
0.7
25
0.004
 
15
1,000
25
0.02
150
7760
J
1.0
6.0
 
500
0.5
50
0.005
 
20
750
7.0
0.03
350
5101
L
0.5
2.0
 
1,000
0.1
20
0.02
 
25
150
18
0.08
700
5949†
K
0.5
4.0
 
1,000
0.1
30
0.02
 
30
150
12
0.08
700
411C
N
0.1
0.5
 
5,000
0.015
20
0.15
 
50
25
20
0.7
18,000
7795
M
0.1
1.0
 
5,000
0.015
25
0.15
 
60
25
15
0.8
18,000
3525
L
0.1
2.0
 
5,000
0.004
25
0.5
 
100
6.0
15
2.5
18,000
7810
K
0.1
4.0
 
5,000
0.007
50
0.4
 
150
10
7.0
2.0
18,000
7655
J
0.1
6.0
 
5,000
0.007
100
0.4
 
175
10
4.0
2.0
35,000
5008C
N
0.01
0.5
 
50,000
0.005
150
1.0
 
150
7.5
3.0
4.2
250,000
7800
M
0.01
1.0
 
50,000
0.003
175
0.8
 
125
5.0
2.0
4.0
140,000
4160
L
0.01
2.0
 
50,000
0.001
200
2.5
 
300
1.5
2.0
15.0
1,000,000
7815
K
0.01
4.0
 
50,000
0.001
200
3.0
 
400
1.5
2.0
15.0
2,000,000
7450
J
0.01
6.0
 
50,000
0.001
250
3.0
 
400
1.5
1.5
12
2,000,000
5664
L
0.001
2.0
 
200,000
0.00025
250
8.0
 
500
0.4
1.5
35
1,000,000

  • Accuracy +1%, initial pulse response for all models, with a high impedance load such as 1 megOhm in parallel with 20 pF. A 50 Ohm termination will reduce the output to half.   
     
  • Droop:   For a flat top current pulse, the output voltage decays toward zero. Initially, the decay appears linear and the slope is referred to as the droop rate.  
     
  • Usable Rise Time: If the 10 to 90% rise time is greater than the specified usable rise time, initial overshoot will be less than 10% of the pulse amplitude.
     
  • † =  Type N Connector  
     

 

Supporting Documents

Particle Accelerator
The Particle Accelerator community uses Pearson Current Monitors for a variety of applications in the area of high . . .
 
Medical Applications
The medical equipment industry uses Pearson Current Transformers in several applications. These include medical. . .
 
Power Industry
The Power Industry uses Pearson Current Transformers to measure transients in switching gear and the observation of. . .
 
EMC Industry
Pearson Clamp-on Current Probes are used to make accurate AC current measurements to meet many of the EMI standards. . .
 
Plasma Research
Pearson Current Probes are used by the Semiconductor and Semiconductor Equipment Industry to make measurements at. . .
 
Capacitive Discharge
Pearson Current Monitors are used to view faithful waveforms and make accurate current measurements from a capacitive. . .
 
Surge Current Testing
Wide Band Current Probes measure surge and in-rush currents for EMC and other industries. A typical requirement. . .
 
Lightning Discharge
Broad Band Current Transformers | Monitors are used to characterize lightning strikes at the Kennedy Space Center and leading. . .
 
Beam Instrumentation
Custom Wide Band Current Monitors are use beam tube applications with our large aperture clamp-on Current Monitors. . .